School and Campus Mechanical Installation

Classroom fresh air, laboratory extraction and canteen loads are calculated separately on the same campus.

Educational Institutions

School ventilation, classroom indoor air quality, laboratory extraction and campus fire protection.

School and campus mechanical installationA school ventilation system keeps classroom CO2 levels and winter indoor temperature stable throughout the lesson. Doğtek Engineering installs mechanical, fire protection and electrical systems in private schools, high schools, universities and campuses according to the different loads of classrooms, laboratories, canteens and sports halls.

An educational building is not occupied at night like a hotel; in the morning hundreds of students enter at once. Corridor loads peak during breaks, laboratories need local extraction, and canteen air must not leak into classrooms. The design follows this rhythm.

Classroom indoor air quality

Rising carbon dioxide in a closed classroom is a common cause of poor concentration and headaches. Classroom ventilation combines fresh air per person, air handling units with heat recovery and quiet grilles. Opening windows alone is not enough; on a noisy street, filtered mechanical ventilation separates indoor air from outdoor noise.

Mechanical scope

  • Classroom and laboratory ventilation
  • Heating, cooling and hot water
  • Canteen and kitchen extraction
  • Fresh air for sports and conference halls
  • Fire hose cabinets, sprinklers and stair pressurisation

Electrical scope

  • Campus power distribution
  • Classroom and laboratory lighting
  • Emergency lighting and fire detection
  • Data, public address and security infrastructure
  • Earthing and power factor correction

Laboratories and fire protection

In science laboratories, fume cupboards and chemical cabinets need extraction separate from general classroom air. In libraries and archives, the fire scenario may shift from wet sprinklers to gas suppression. School fire protection is planned together with assembly areas, escape stairs and evacuation of people with disabilities.

Campus operation

Summer holidays and exam periods use the same boiler room. The time schedule should throttle pumps and air handling units in an empty building, while keeping laboratory extraction on when experiments are running. This distinction is the automation scenario of a school's mechanical systems.

Education references

Fikri Bilim College, İTO Anatolian İmam Hatip High School, Era College, Uludağ University, Bezmiâlem Vakıf University and Biruni University are among our education references. The common basis of mechanical services is described on the mechanical systems page.

Frequently asked questions

Why does a school need a ventilation system?

CO2 rises quickly in a crowded classroom. Mechanical fresh air keeps indoor air quality stable during the lesson, independent of windows, and keeps street noise out.

Why is laboratory ventilation separated from classrooms?

Fume cupboards and chemical cabinets must be exhausted through the roof without mixing with general classroom air; otherwise odours and pollutants spread into corridors.

What does fire protection in an educational building cover?

Escape stairs, fire hose cabinets, detection, public address and, where required, sprinklers or gas suppression are planned together. Assembly and evacuation scenarios are linked to the electrical system.

Are campus mechanical systems switched off in summer?

An empty building can be put into setback mode. Laboratory extraction and fire systems stay in operation as required by use and regulations.